Test results

 

1

 

COMPONENT CONCERNED

 

COOLANT LEVEL CHECK AND CLIMATE CONTROL SYSTEM CIRCUIT PRESSURE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Climate control system circuit

 

Switch on the climate control system (with engine on) for 10-15 minutes.

Switch it off and wait for 45 minutes.

Connect the climate control system repressurising station and check that the readings of the pressure values are compatible with the vehicle specifications (if there are no specifications, refer to the table below)

 

Go to Step 2

 

The pressure values do not comply with the required specifications

 

Empty the circuit, create vacuum and restore the correct coolant pressurisation

 

External temperature (ºC)

 

LP and HP with AC OFF (bar)

 

20

 

4.5 - 5

 

25

 

5.5 - 6

 

30

 

6.5 - 7

 

35

 

7.5 - 8

 

40

 

˜ 9

 

2

 

COMPONENT CONCERNED

 

CLIMATE CONTROL SYSTEM CIRCUIT PARAMETER CHECK WITH PRESSURISING STATION

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Climate control system circuit

 

Switch on the climate control system (with engine running at 1500 rpm) with the minimum fan speed and the lowest temperature.

Connect the climate control system repressurising station to the climate control system circuit and check that the readings of the temperature and pressure values are correct.

 

Go to Step 3

 

Pressure levels incorrect

 

Refer to the checklist

 See table L007 Impianto climatizzazione funziona ma raffredda lentamente

 

DeltaT (ºC)

 

Low Pressure (LP) (bar)

 

High Pressure (HP) (bar)

 

>8

 

1-3

 

10-14

 

3

 

COMPONENT CONCERNED

 

CLIMATE CONTROL SYSTEM OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Climate control system

 

Check whether the customer claims about moisture in the passenger compartment

 

End of diagnosis

 

Moisture in the passenger compartment

 

Go to Step 4

 

4

 

COMPONENT CONCERNED

 

CLIMATE CONTROL SYSTEM DRAIN OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Climate control system drain

 

Check the correct operation of the climate control system drain, specifically check that it is not obstructed

 

End of diagnosis

 

The climate control system drain is not operating correctly

 

Restore the correct operation of the climate control system drain or, where necessary, replace it.

Op. 5040C68 CONDENSATE DRAIN PIPE AND ANITI-CONDENSATION FILTER - ARRANGE