Test results

 

1

 

COMPONENT CONCERNED

 

OXYGEN SENSOR CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Oxygen sensor wiring

 

Check the continuity/insulation of the wiring between sensor heater coil and engine management control unit

 

Go to Step 2

 

Wiring defective

 

Restore the correct wiring

 

2

 

COMPONENT CONCERNED

 

OXYGEN SENSOR CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Oxygen sensor wiring

 

Check that the sensor heater coil power supply is correct

 

Go to Step 3

 

Power supply not correct

 

Restore correct power supply

 

3

 

COMPONENT CONCERNED

 

OXYGEN SENSOR CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Oxygen sensor

 

Check that the sensor is working

 

End of diagnosis

 

Oxygen sensor faulty

 

Replace the oxygen sensor

Op. 1080B90 LAMBDA SENSOR - R.R.