Test results |
|
|
Intake duct |
Check for leaks in the intake duct downstream of the flow meter |
Go to Step 2 |
Leaks |
Restore the correct operation of the intake duct |
|
|
Airflow meter |
Check that the airflow meter is working properly |
Go to Step 3 |
Airflow meter not working properly |
Replace the airflow meter Op. 1060G10 AIR FLOW METER - R.R. |
|
|
High pressure EGR valve |
Connect the diagnostic tool to the powertrain control module, go to the “ACTUATORS” menu and launch procedure “EGR DC Motor test”. Check the outcome of the test |
Go to Step 4 |
The test did NOT have a positive outcome |
Replace the high pressure EGR valve Op. 1080C24 E.G.R. SYSTEM SOLENOID - R + R |
|
|
High pressure EGR valve |
Check for other error codes stored in the powertrain control module |
End of diagnosis |
Additional errors stored in the Powertrain Control Module |
Follow the instructions provided by the diagnostic tool to resolve the errors |