Test results

 

1

 

DISTRIBUTION FLAP OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the distribution flap is working correctly

 

Go to Step 2

 

Distribution flap damaged or not working correctly

 

Replace the distribution flap

Op. 5040D51 A/C SYSTEM LEFT AIR DISTRIBUTION FLAP LINKAGE/GEAR - R.R.

 

2

 

CLIMATE CONTROL SYSTEM CONTROL OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the climate control system control is working correctly; specifically check that the gears are not damaged

 

Go to Step 3

 

Control gears damaged or not working correctly

 

Replace the faulty gears

 

3

 

BOWDEN CABLE OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the Bowden cables are working correctly; specifically check that there are no wrong paths of the Bowden cable

 

Go to Step 4

 

Bowden cable not positioned correctly

 

Reposition the Bowden cable correctly or replace it if necessary

 

4

 

LEVER POSITION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the Bowden cable is correctly positioned on the levers, both on the casing and on the control

 

End of diagnosis

 

Bowden cable positioning fault

 

Restore the correct position of the levers on the casing or on the control