APPLICABLE TO VERSIONS WITH: Automatic Air Conditioning

     

Test results

 

1

 

DISTRIBUTION FLAPS OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check, with the engine running, that the distribution flaps are working correctly

 

Go to Step 2

 

Distribution flaps damaged

 

Restore correct operation of the distribution flaps or replace the distribution actuator

Op. 5040D76 AIR CONTITIONING DISTRIBUTION FLAP CONTROL MOTOR - R.R.

 

2

 

LEVER POSITION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the levers are positioned correctly both on the casing and on the control

 

Go to Step 3

 

Levers not positioned correctly

 

Reposition the levers correctly on the casing and on the control

 

3

 

ACTUATORS OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the distribution actuators are working correctly

 

Go to Step 4

 

Distribution actuators not working correctly

 

Replace the distribution actuators

Op. 5040D76

 

4

 

FOREIGN BODIES CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check for the presence of foreign bodies under the dashboard preventing the actuators from moving

 

Go to Step 5

 

Presence of foreign bodies preventing correct motion

 

Remove the foreign bodies and check that operation has been restored

 

5

 

CLIMATE CONTROL SYSTEM CONTROL UNIT OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the climate control system control unit is working correctly

 

End of diagnosis

 

The climate control system control unit is not working correctly

 

Replace the climate control unit

Op. 5040D14 CONTROL UNIT WITH AUTOMATIC AIR CONDITIONING CONTROL PANEL - R.R.