Test results |
|
|
Engine management control unit |
Check if "Overtemperature" is shown in the error details |
Go to Step 1 |
The error detail is "Overtemperature" |
Go to Step 4 |
|
|
Throttle valve wiring |
Check for the presence of short circuit to Vbatt |
Go to Step 2 |
Presence of short circuit to Vbatt. |
Restore correct insulation to battery positive |
|
|
Throttle valve wiring |
Check for short circuits to earth |
Go to Step 3 |
Presence of short circuit to earth |
Restore correct insulation to earth |
|
|
Throttle valve wiring |
Check for an open circuit |
Go to Step 4 |
Presence of open circuit |
Restore the correct connections |
|
|
Motorised throttle |
Connect the diagnosis equipment to the engine management control unit, enter Active Diagnosis and perform the motorised throttle test |
End of diagnosis |
Motorised throttle faulty |
Replace the motorised throttle Op. 1060G50 THROTTLE BODY - R.R |