Test results

 

1

 

COMPONENT CONCERNED

 

WIRING CHECK BETWEEN HIGH PRESSURE EGR SOLENOID VALVE CONTROL AND ENGINE CONTROL MODULE

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Wiring between high pressure EGR valve control and powertrain control module

 

Check the continuity of the wiring between high pressure EGR valve control and PIN 35.50 of the engine control module

 

Go to Step 2

 

Breaks in the wiring continuity

 

Restore the correct continuity of the wiring

 

2

 

COMPONENT CONCERNED

 

CHECK USING DIAGNOSIS EQUIPMENT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

High pressure EGR valve

 

Connect the diagnostic tool to the powertrain control module, go to the “ACTUATORS” menu and launch procedure “EGR DC Motor test”. Check the outcome of the test

 

Go to Step 3

 

The test did NOT have a positive outcome

 

Replace the high pressure EGR valve

 Op. 1080C24 E.G.R. SYSTEM SOLENOID - R + R

 

3

 

COMPONENT CONCERNED

 

CHECK USING DIAGNOSIS EQUIPMENT

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

High pressure EGR valve

 

Check for other error codes stored in the powertrain control module

 

End of diagnosis

 

Additional errors stored in the Powertrain Control Module

 

Follow the instructions provided by the diagnostic tool to resolve the errors