Test results |
|
|
Check that the mixing flap is working correctly |
Go to Step 2 |
Mixing flap damaged or not working correctly |
Replace the mixing flap Op. 5040D44 AIR CONDITIONER RIGHT AIR MIXER FLAP CONTROL LINKAGE/MECHANISM - R.R. |
|
|
Check that the climate control system control is working correctly; specifically check that the gears are not damaged. |
Go to Step 3 |
Control gears damaged or not working correctly |
Replace the faulty gears |
|
|
Check that the Bowden cables are working correctly; specifically check that there are no wrong paths of the Bowden cable. |
Go to Step 4 |
Bowden cable not positioned correctly |
Reposition the Bowden cable correctly or replace it if necessary |
|
|
Check that the Bowden cable is correctly positioned on the levers, both on the casing and on the control |
End of diagnosis |
Bowden cable positioning fault |
Restore the correct position of the levers on the casing or on the control |