Test results

 

1

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor wiring

 

Check for an open circuit

 

Go to Step 2

 

Presence of open circuit

 

Restore the correct connections

 

2

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor wiring

 

Check for short circuits to Vbatt

 

Go to Step 3

 

Presence of short circuit to Vbatt.

 

Restore correct insulation to battery positive

 

3

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor wiring

 

Check for short circuits to earth

 

Go to Step 4

 

Presence of short circuit to earth

 

Restore correct insulation to earth

 

4

 

COMPONENT CONCERNED

 

DIFFERENTIAL PRESSURE SENSOR OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor

 

Check correct operation of the differential pressure sensor

 

End of diagnosis

 

Differential pressure sensor incorrectly calibrated

 

Replace the differential pressure sensor

Op. 1080B82