Test results

 

1

 

COMPONENT CONCERNED

 

PIPE UPSTREAM OF PARTICULATE FILTER CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Pipe upstream of particulate filter

 

Check whether the pipe upstream of the particulate filter is correctly connected

 

Go to Step 2

 

Pipe upstream of particulate filter not correctly connected

 

Restore the correct connection for the pipe

 

2

 

COMPONENT CONCERNED

 

PIPE UPSTREAM OF PARTICULATE FILTER CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Pipe upstream of particulate filter

 

Check the condition of the pipe upstream of the particulate filter

 

Go to Step 3

 

Pipe not intact

 

Replace the damaged pipe

 

3

 

COMPONENT CONCERNED

 

ELECTRICAL CHECKS

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor connections

 

Check the condition/presence of oxidation at the connections

 

Go to Step 4

 

Incorrect condition/presence of oxidation at the connections

 

Restore the connections to correct operation

 

4

 

COMPONENT CONCERNED

 

DIFFERENTIAL PRESSURE SENSOR OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Differential pressure sensor

 

Check correct operation of the differential pressure sensor

 

End of diagnosis

 

Differential pressure sensor incorrectly calibrated

 

Replace the differential pressure sensor

Op. 1080B82