Test results

 

1

 

COMPONENT CONCERNED

 

CHECK WIRING TO GLOW PLUG 3

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Glow plug 3 wiring

 

Check for a short circuit to earth on the glow plug 3 wiring

 

Go to Step 2

 

Presence of short circuit to earth

 

Restore correct insulation to earth

 

2

 

COMPONENT CONCERNED

 

CHECK WIRING TO GLOW PLUG 3

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Glow plug 3 wiring

 

Check for an open circuit on the glow plug 3 wiring

 

Go to Step 3

 

Presence of open circuit

 

Restore the correct connections

 

3

 

COMPONENT CONCERNED

 

CHECK OPERATION OF GLOW PLUG 3

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Glow plug 3

 

Check the correct operation of the glow plug 3

 

End of diagnosis

 

Glow plug 3 not working properly

 

Replace the glow plug 3

 Op. 5520C10 HEATER PLUGS - R+R