Test results |
|
|
Amplifier fasteners |
Check that the fixing points for the amplifier have been properly tightened: screws, bands, ties, etc... |
Go to Step 2 |
Incorrect fastening of the amplifier |
Restore the correct fastening of the amplifier |
|
|
Amplifier fasteners |
Check that there are no cracks or slots between the brackets/mounts touching the surfaces of the amplifier or of the bodywork |
Go to Step 3 |
Cracks or slots between the brackets/mounts touching the surfaces of the amplifier or of the bodywork |
Restore the correct fastening of the amplifier by fitting some soft stuffing (foam, rubber, paper) in the relevant areas |
|
|
Amplifier |
Check that operation of the amplifier is correct shaking it to find out possible loose objects inside |
Go to Step 4 |
The amplifier is damaged |
Replace the amplifier Op. 5580T42 BOSE SOUND SYSTEM AMPLIFIER - R.R. |
|
|
Amplifier |
Check that operation of the amplifier is correct identifying contact points or gaps among the different components of the amplifier (holding the amplifier and beating it more times on different points on each side; the response to this movement must be a dull sound, without any vibration). |
End of diagnosis |
The amplifier is damaged |
Replace the amplifier Op. 5580T42 |