Test results |
|
|
Fuel tank |
Check that there is fuel in the tank |
Go to Step 1 |
No fuel in the tank |
Top up the fuel with the correct amount |
|
|
Low pressure circuit |
Check that there are no leaks in the low pressure circuit |
Go to Step 2 |
Leaks from the low pressure circuit |
Restore the sealing of the system |
|
|
Low pressure pump wiring |
Check the continuity of the wiring between pump and dashboard control unit |
Go to Step 3 |
Wiring defective |
Restore the correct wiring |
|
|
Low pressure pump fuse |
Check the condition of the pump fuse |
Go to Step 4 |
Blown pump fuse |
Replace the fuse after ascertaining the cause of the malfunction |
|
|
Low pressure pump relay switch |
Check that the pump relay switch is working correctly |
Go to Step 5 |
Relay defective |
Replace the relay |
|
|
Low pressure pump |
Check that the low pressure pump is working correctly |
Go to Step 6 |
Low pressure pump defective |
Replace the low pressure pump Op. 1040A70 SUBMERGED PUMP ASSEMBLY COMPLETE WITH LEVEL GAUGE CONTROL - R + R |
|
|
Diesel filter |
Check that the over-flow valve at the diesel filter is not blocked open |
Go to Step 7 |
Filter valve blocked open |
Replace the diesel fuel filter Op. 1044B10 FUEL FILTER ASSEMBLY - R.R. OR REPLACE |
|
|
Diesel filter |
Check that the diesel filter is not obstructed |
Go to Step 8 |
Diesel filter clogged |
Replace diesel filter Op. 1044B10 FUEL FILTER ASSEMBLY - R.R. OR REPLACE |
|
|
Fuel pipe |
Check that the fuel pipe is not obstructed |
Go to Step 9 |
Fuel pipe obstructed |
Restore the fuel pipe to correct operation |
|
|
Injectors |
Check that the injector recirculation is not excessive and that the injectors are not blocked open |
Go to Step 10 |
Injectors defective |
Replace the injectors Op. 1060F11 INJECTOR ONE R R |
|
|
Pressure regulator |
Check that the pressure regulator is working correctly |
Go to Step 11 |
Regulator faulty |
Replace the high pressure pump Op. 1060E10 |
|
|
High pressure pump |
Check that the high pressure pump is working correctly |
End of diagnosis |
High pressure pump faulty |
Replace the high pressure pump Op. 1060E10 |