Test results

 

1

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Fan 1 wiring

 

Check for the presence of short circuit to Vbatt

 

Go to Step 2

 

Presence of short circuit to Vbatt.

 

Restore correct insulation to battery positive

 

2

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Fan 1 wiring

 

Check for short circuits to earth

 

Go to Step 3

 

Presence of short circuit to earth

 

Restore correct insulation to earth

 

3

 

COMPONENT CONCERNED

 

ELECTRICAL CONNECTION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Fan 1 wiring

 

Check for an open circuit

 

Go to Step 4

 

Presence of open circuit

 

Restore the correct connections

 

4

 

COMPONENT CONCERNED

 

COOLING FAN RELAY SUPPLY CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Cooling fan relay

 

Check that the cooling fan relay is receiving the correct power supply

 

Go to Step 5

 

Cooling fan relay supply not correct

 

Restore the correct cooling fan relay supply

 

5

 

COMPONENT CONCERNED

 

COOLING FAN RELAY OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Cooling fan relay

 

Check that the cooling fan relay is working correctly

See E5020 ENGINE COOLING

 

End of diagnosis

 

Cooling fan relay not working correctly

 

Replace the cooling fan relay