Test results |
|
|
EGR valve connections |
Check that the connections are not faulty |
Go to Step 2 |
Faulty connections |
Restore the correct connections |
|
|
EGR valve connections |
Check the wiring continuity |
Go to Step 3 |
Faults in the continuity of the wiring |
Restore the correct continuity of the wiring |
|
|
EGR valve connections |
Check that the wiring is correctly insulated |
Go to Step 4 |
Wiring insulation not correct |
Restore the correct insulation for the wiring |
|
|
EGR Valve |
Check that the EGR valve is working properly by carrying out the See Test 1080CB E.G.R. SOLENOID FUNCTIONAL TEST |
Go to Step 5 |
EGR valve not working correctly |
Replace the EGR valve Op. 1080C24 E.G.R. SYSTEM SOLENOID - R + R |
|
|
High pressure EGR valve |
Connect the diagnostic tool to the powertrain control module, go to the “ACTUATORS” menu and launch procedure “EGR DC Motor Offset Learning”. Check the outcome of the test |
Go to Step 6 |
The test did NOT have a positive outcome |
Replace the high pressure EGR valve Op. 1080C24 E.G.R. SYSTEM SOLENOID - R + R |
|
|
High pressure EGR valve |
Check for other error codes stored in the powertrain control module |
End of diagnosis |
Additional errors stored in the Powertrain Control Module |
Follow the instructions provided by the diagnostic tool to resolve the errors |