Test results

 

1

 

CHECK CLEANLINESS OF FAN AND SPIRAL

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check the cleanliness of the fan and spiral

 

Go to Step 2

 

Dirty fan or spiral

 

Clean the fan and the spiral

 

2

 

CHECK FOR FOREIGN BODIES ON FAN OR SPIRAL

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check for the presence of foreign bodies, deposits of dust on the fan vanes and/or on the spiral.

Do not spray any kind of lubricant to eliminate the noise

 

Go to Step 3

 

Foreign bodies present

 

Remove the foreign bodies found and restore correct operation

 

3

 

PASSENGER COMPARTMENT NOISE CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check all the components of the passenger compartment near the climate control system that may cause noise/vibration such as ducts, air distribution vents, which might be clogged, and the instrument panel

 

End of diagnosis

 

Noisy component found

 

Eliminate the noise securing or replacing the faulty component