Test results

 

1

 

FAN WIRING CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Connect the diagnosis equipment to the climate control system control unit and check whether there are specific errors related to the fan

 

Go to Step 2

 

Errors related to the fan found

 

Proceed as instructed by the diagnosis tool

 

2

 

FAN WIRING CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Fan electrical wiring connections check

Disconnect/reconnect the fan wiring.

 

Go to Step 3

 

Fault detected in the fan wiring

 

Restore the correct wiring of the fan

 

3

 

FAN OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the fan rotates at all speeds by activating it using the switch

 

Go to Step 4

 

The fan does not work at max. speed

 

Check the condition of the vehicle fuse and replace it, if necessary

 

4

 

CERAMIC RESISTOR CONDITION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check the condition of the ceramic resistor

 

Go to Step 5

 

Ceramic resistor not working correctly

 

Replace the ceramic resistor

Op. 5040C44 FAN MOTOR ELECTRONIC VARIATOR - R+R

 

5

 

CURRENT UPTAKE FAULTS CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check all the components in the vehicle's electrical system that may cause irregular/excessive current uptake, such as: battery and alternator.

 

Go to Step 6

 

Fault found on the component

 

Replace the component that causes the fault

 

6

 

CLIMATE CONTROL SYSTEM CONTROL UNIT OPERATION CHECK

 

OK (NO FAULTS DETECTED)

 

FAULT DETECTED

 

OPERATION

   

Check that the climate control system control unit is working correctly

 

End of diagnosis

 

Climate control system control unit not working properly

 

Replace the climate control system control unit

Op. 5040D14 CONTROL UNIT WITH AUTOMATIC AIR CONDITIONING CONTROL PANEL - R.R.