Test results |
|
|
Supercharging sensor wiring |
Check the continuity/insulation of the wiring between the turbo sensor and the engine management control unit |
Go to Step 2 |
Wiring defective |
Restore the correct wiring |
|
|
Turbocharging sensor |
Check the correct operation of the overpressure sensor by carrying out the See Test 1064BA |
Go to Step 3 |
Sensor defective |
Replace the supercharging pressure sensor |
|
|
Turbocharger |
Check that the turbocharger is working properly |
Go to Step 4 |
Turbocharger defective |
Replace turbocharger Op. 1064A10 TURBO CHARGER - R + R |
|
|
Atmospheric pressure sensor |
Check that the atmospheric pressure sensor is working properly by connecting an Examiner to the engine management control unit |
End of diagnosis |
Atmospheric pressure sensor faulty |
Replace the engine management control unit Op. 1060G80 |