Removing ( Refitting )

- Position the vehicle on the lift.

Op. 5530B54

- Disconnect the negative battery terminal.

   

Description

 

Connector

 

-

 

BATTERY

 

See A001

Op. 7055B51

   Op. 5010B12 CLIMATE CONTROL UNIT AIR INTAKE DUCT - R.R.

   Op. 1064B31 WASTEGATE SOLENOID VALVE GUARD - R.R.

   Op. 1064B35 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE VALVE - R.R.

   Op. 1064B36 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE ACTUATOR - R.R.

   Op. 1064B44 WASTE GATE VALVE ACTIVATION SOLENOID VALVE - R.R.

   Op. 1064B30 WASTEGATE SOLENOID VALVE MOUNTING BRACKET - R.R.

   Op. 1048A39 SLEEVE FROM AIR CLEANER TO RIGID PIPE - R R

   Op. 1048A38 PIPE BETWEEN AIR FILTER/FLOW METER - R.R.

   Op. 1060G10 AIR FLOW METER - R.R.

   Op. 1048A42 SLEEVE FROM FLOW METER TO TURBO CHARGER AIR INLET PIPE - R + R

   Op. 1016A10 SOUND-PROOFING COVER - R.R

   Op. 1008C30 POWER UNIT LOWER REACTION ROD - R.R.




1. Disconnect the electrical connection for the E.G.R. solenoid valve.

   

Description

 

Connector

 

1

 

EGR SOLENOID VALVE

 

See L030

2. Open the bands and disconnect the hoses for the differential pressure sensor.

3. Undo the fixing screws (3a) and (3b) and remove the pipe from EGR solenoid valve to air chamber (3c) complete with gaskets.

Refitting ( Removing )

- Fit the pipe from EGR solenoid valve to air chamber with new gaskets and tighten the fixing screws.

- Connect the differential pressure sensor hoses and close the bands.

- Connect the electrical connection for the EGR solenoid valve.

   

Description

 

Connector

 

-

 

EGR SOLENOID VALVE

 

See L030

    Op. 1008C30 POWER UNIT LOWER REACTION ROD - R.R.

    Op. 1016A10 SOUND-PROOFING COVER - R.R

    Op. 1048A42 SLEEVE FROM FLOW METER TO TURBO CHARGER AIR INLET PIPE - R + R

    Op. 1060G10 AIR FLOW METER - R.R.

    Op. 1048A38 PIPE BETWEEN AIR FILTER/FLOW METER - R.R.

    Op. 1048A39 SLEEVE FROM AIR CLEANER TO RIGID PIPE - R R

    Op. 1064B30 WASTEGATE SOLENOID VALVE MOUNTING BRACKET - R.R.

    Op. 1064B44 WASTE GATE VALVE ACTIVATION SOLENOID VALVE - R.R.

    Op. 1064B36 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE ACTUATOR - R.R.

    Op. 1064B35 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE VALVE - R.R.

    Op. 1064B31 WASTEGATE SOLENOID VALVE GUARD - R.R.

    Op. 5010B12 CLIMATE CONTROL UNIT AIR INTAKE DUCT - R.R.

Op. 7055B51

- Connect the negative battery terminal.

   

Description

 

Connector

 

-

 

BATTERY

 

See A001

Op. 5530B54

- Remove the vehicle from the lift.