Removing
(
Refitting
)
- Position the vehicle on the lift. Op. 5530B54 - Disconnect the negative battery terminal.
Op. 7055B51 |
![]() |
![]() |
![]() |
Op. 1064B35 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE VALVE - R.R. |
![]() |
Op. 1064B36 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE ACTUATOR - R.R. |
![]() |
Op. 1064B44 WASTE GATE VALVE ACTIVATION SOLENOID VALVE - R.R. |
![]() |
Op. 1064B30 WASTEGATE SOLENOID VALVE MOUNTING BRACKET - R.R. |
![]() |
![]() |
![]() |
![]() |
Op. 1048A42 SLEEVE FROM FLOW METER TO TURBO CHARGER AIR INLET PIPE - R + R |
![]() |
![]() |
![]() |
![]() |
1. Disconnect the electrical connection for the water supply actuator control solenoid valve to the EGR heat exchanger.
2. Disconnect the vacuum pipe for EGR heat exchanger water supply actuator control. |
![]() |
1. Disconnect the vacuum pipe for wastegate solenoid valve control. |
![]() |
1. Disconnect the vacuum pipe from the vacuum reservoir. 2. Undo the screw (2a) fixing the oil dipstick tube (2b) to the vacuum reservoir. 3. Undo the screws (3a) and remove the EGR system exhaust gas/water heat exchanger (3b) complete with radiant pack and gaskets. |
![]() |
Refitting
(
Removing
)
1. Place the exhaust gas/water heat exchanger (1a) for the EGR system, complete with radiant pack and new gaskets, back in its housing and tighten the fixing screws (1b) to the prescribed torque.
2. Tighten the screw (2a) fixing the oil dipstick tube (2b) to the vacuum reservoir. 3. Connect the vacuum pipe to the vacuum reservoir. |
|
- Connect the vacuum pipe for wastegate solenoid valve control. - Connect the vacuum pipe for EGR heat exchanger water supply actuator control. - Connect the electrical connection for the water supply actuator control solenoid valve to the EGR heat exchanger.
|
![]() |
![]() |
Op. 1048A42 SLEEVE FROM FLOW METER TO TURBO CHARGER AIR INLET PIPE - R + R |
![]() |
![]() |
![]() |
![]() |
Op. 1064B30 WASTEGATE SOLENOID VALVE MOUNTING BRACKET - R.R. |
![]() |
Op. 1064B44 WASTE GATE VALVE ACTIVATION SOLENOID VALVE - R.R. |
![]() |
Op. 1064B36 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE ACTUATOR - R.R. |
![]() |
Op. 1064B35 PRESSURIZED AIR SUPPLY PIPE TO WASTE GATE VALVE - R.R. |
![]() |
![]() |
![]() |
![]() |
Op. 7055B51 - Connect the negative battery terminal.
Op. 5530B54 - Remove the vehicle from the lift. |
Removing