Removing ( Refitting )

If the diesel electronic injection system control unit is being replaced, before it is removed, an Examiner must be connected and the "Replace Control unit" procedure must be launched (this operation recovers the data referring to the Engine Oil wear status and stores it in the new control unit). If the outcome of this procedure is negative, the Engine Oil and Filter must be replaced as there is no record of historical data.

For this reason once the replacement has been completed, the "Engine Oil Replacement" function must be updated using the Examiner diagnostic instrument set to the mode for the specific engine management control unit.


    Op. 1016A10 SOUND-PROOFING COVER - R.R

1. Disconnect the electrical connections from the injection control unit.

   

Description

 

Connector

 

1

 

Engine management control unit

 

   See M010 ENGINE MANAGEMENT CONTROL UNIT

2. Undo the nuts and remove the injection control unit.

Refitting ( Removing )

- Place the injection control unit back in its housing and secure it to the mounting bracket using the nuts.

- Connect the electrical connections to the control unit.